Dosing pump PDE eONE MА 07-10 100/250V
Brand:
ETATRON D.S.Characteristics
Producer:
ETATRON D.S.
Input 4-20 mA:
No
Output service relay:
No
Power supply:
1х220 V, 50 Hz
Power capacity, Wt:
7/26
Control:
Manual
Pulse input(From Flowmetwer):
So
See all
Documentation
Categories
Favorite
Compare
Products from the same category
Also buy with this product
Exchange or returnWe will return or exchange for another product
Fast shippingWe will pick up and send promptly
Warranty and qualityGuaranteed return of goods within 10 days
On-line payment on the sitePayment is made by bank cards
Features Dosing pump PDE eONE MА 07-10 100/250V
Producer | ETATRON D.S. |
Input 4-20 mA | No |
Output service relay | No |
Power supply | 1х220 V, 50 Hz |
Power capacity, Wt | 7/26 |
Control | Manual |
Pulse input(From Flowmetwer) | So |
Support for flow sensor | No |
Input foe sensor PH | No |
Model | MА |
Input for sensor RX | No |
Flow rate, l/h | 7 |
Dosage mode: Continually ON-OFF | So |
Input foe sensor | No |
Pressure, bar | 10 |
Pump body material | PVDF |
Dosage mode: proportional PROP | So |
Input for sensor CD | No |
Impulse volume | 0,39 |
Product regulation 0-100% | So |
Input foe temperature sensor | No |
Material | PVDF |
Input for level sensor reagent | So |
Input mA | No |
Number of pulses | 300 |
Serial number of the pump | eONE |
Country of Origin | Italy |
PumpType | dosing solenoid |
Drive Type | electric |
Availability of spare parts | yes |
Application | hypochlorite, algicide, acids, of hydrochloric acid, alkalis, caustic, coagulant |
Analogue for | Injecta, Emec, AquaViva, Descon trol S, Seko, ASeko, FWT |
Weight, kg | 4,5 |
Description Dosing pump PDE eONE MА 07-10 100/250V
Dosage mode:
- Manual ON /OFF with a double scale of 10-100% and 2-20% performance adjustment (a micro-controller is used for clearer adjustment of pump performance)
- Proportional to 1:1 from the pulse flow meter (one received pulse from the flow meter = 1 pump injection). The pump is equipped with protection functions (on/off):
UNDERLOAD-monitoring the absence of the dosed reagent on the intake line; OVERLOAD – monitoring the excess of the permissible back pressure in the system.
Maximum pulse frequency 300 imp / min
Power consumption 26 W (varies depending on the back pressure)
Level sensor support (sensor not included).
Documentation Dosing pump PDE eONE MА 07-10 100/250V
Download instructions, catalog for Dosing pump PDE eONE MА 07-10 100/250V
Dosing pump PDE eONE MА 07-10 100/250V reviews
Help in selection
+38 067 360-71-01
Selection of mechanical seals
+38 095 656-37-57
Pump selection
If you have any questions when placing an order, or need help choosing a product, please contact the specified contacts.