EMEC LOTUS AIR chlorine dioxide dosing and control system 10-60 g/h, for water disinfection
Brand:
EMECCharacteristics
Producer:
EMEC
Series:
LOTUS AIR
Country of Origin:
Italy
Documentation
Categories
Favorite
Compare
Products from the same category
Also buy with this product
Exchange or returnWe will return or exchange for another product
Fast shippingWe will pick up and send promptly
Warranty and qualityGuaranteed return of goods within 10 days
On-line payment on the sitePayment is made by bank cardsFeatures EMEC LOTUS AIR chlorine dioxide dosing and control system 10-60 g/h, for water disinfection
Producer | EMEC |
Series | LOTUS AIR |
Country of Origin | Italy |
Description EMEC LOTUS AIR chlorine dioxide dosing and control system 10-60 g/h, for water disinfection
The LOTUS AIR pressureless system produces, doses and controls chlorine dioxide for water disinfection based on circulating water. It can be equipped with a ClO2 sensor (SVCL2 or SVCL17) or an mV sensor (ERH), a sensor holder and a filter. There is no need to handle chlorine dioxide as a gas, instead two diluted “precursor” chemicals, hydrochloric acid (HCl 9%) and sodium chlorite (NaClO2 7.5%), react with each other in a reaction chamber to form the required chlorine dioxide. The LOTUS AIR reaction process takes place at ATMOSPHERIC PRESSURE. The chlorine dioxide produced by the LOTUS AIR is stored in a tank and then dosed proportionally to the demand. A multi-function valve guarantees process safety. Dosage is proportional to the volumetric flow rate. Chlorine dioxide is produced in a BATCH process. An activated carbon filter prevents potential evaporation. Features: - Batch production of chlorine dioxide. - ClO2 dosing in proportional mode. - Multi-point injection. - Alarms: products, water, emptying. - Water meter input. - Backup power input. - Real-time production data. - ClO2 sensor readings (LOTUS AIR SVCL2 - LOTUS AIR SVCL17). - Temperature sensor readings (sensor and accessories not included). - mV sensor readings (LOTUS AIR ERH). - Monitoring of SEFL pumps and flow sensors. - Maintenance interval. - LOTUS AIR control unit. - ERMES communication ClO2 concentration measurement. - PVDF ball valve for emptying the reaction chamber. - ClO2 concentration: 2 g/l (0.2%). - LOTUS AIR control unit. - 3 dosing pumps: red HCl pump, blue NaClO2 pump and grey. - ClO2 pump. - Multifunction valve (MFKT/V). - Double chamber: reaction and storage. - Housing in ASA (acrylonitrile-styrene-acrylate) or fiberglass (Lotus Air 30/60 models). - IP65 (NEMA4x) protection of the LOTUS control unit. - ENCODER wheel control. - Operating temperature: 0-45 °C (32-110 °F).
Documentation EMEC LOTUS AIR chlorine dioxide dosing and control system 10-60 g/h, for water disinfection
Download instructions, catalog for EMEC LOTUS AIR chlorine dioxide dosing and control system 10-60 g/h, for water disinfection
EMEC LOTUS AIR chlorine dioxide dosing and control system 10-60 g/h, for water disinfection reviews

Help in selection
+38 067 360-71-01
Selection of mechanical seals
+38 095 656-37-57
Pump selection
If you have any questions when placing an order, or need help choosing a product, please contact the specified contacts.
















































































































