BEDJ 100/8-15-27-3 (6 l/s, 80m, 11kW) Fire Fighting System
Brand:
BTS EngineeringCharacteristics
Producer:
BTS Engineering
Nom.head, m:
80
Power supply:
3х380 V, 50 Hz
Feed height, m:
80
Nom.flow rate, m3/h:
23
Power capacity, kW:
11
Diesel pump power, kW:
20
See all
Documentation
Favorite
Compare
Products from the same category
Also buy with this product
Exchange or returnWe will return or exchange for another product
Fast shippingWe will pick up and send promptly
Warranty and qualityGuaranteed return of goods within 10 days
On-line payment on the sitePayment is made by bank cards
Features BEDJ 100/8-15-27-3 (6 l/s, 80m, 11kW) Fire Fighting System
Producer | BTS Engineering |
Nom.head, m | 80 |
Power supply | 3х380 V, 50 Hz |
Feed height, m | 80 |
Nom.flow rate, m3/h | 23 |
Power capacity, kW | 11 |
Diesel pump power, kW | 20 |
Pump capacity, cu.m/hour | 23 |
Jockey pump power, kW | 2,2 |
Max.temperature, C | 120 |
Specific fuel consumption in g/kWh | 204 |
Material | cast iron |
Country of Origin | China |
Warranty, months | 12 |
Application | firefighting, emergency water supply |
Analogue for | SIHI, Hydro-Vacuum, HYPRO, Inoxpa, Johnson, Kenle, KOLMEKS, GEA, Grundfos, Hidrostal, Hilge, Hobart, Honda, Alweller, Ebara, Flygt, Odwerk, Varna, ASTA, Aquatechnika, Aquario, APV, ALLWEILER, DPPumps, Foras, DAB, Cornell, Caprari, Calpeda, Bronzoni, FRISTAM, Omnigena, Nocchi, Unitech, Sterling, Zenit, OMAC, Greenpumps, TAJFUN, TEREX, ThuneEureka, VARISCO, LOWARA, WILO, KSB, Kripsol, Rovatti, PERKINS, Pentax, PentairSwimmey, Packo, Onga, Svanehoj, Sprut, Speroni, SOMA, Simaco, SAER |
Description BEDJ 100/8-15-27-3 (6 l/s, 80m, 11kW) Fire Fighting System
BEDJ Version:
Fire pump set consists of Electric pump+Diesel pump+Jockey pump and all accessories
DESCRIPTION:
- Fire pumps are designed for whole operational life, the maximum reliability is always the first priority
- The components affixed onto a steel framing structure
- Each controller has its own individual pressure sensing line
- The suction line should never include a strainer
- Check valve and butterfly valve in the discharge line
- NFPA 20 not allows suction from negative level for end suction and split case pumps
PRINCIPLE:
When pressure drops below the set value, jockey starts running with the signal from the pressure switch and continues running for 10 minutes till the system pressure reaches the set value. If the pressure continues drop, first the main pump starts to run. If the system pressure can't supply and pressure continues drop,the standby pump starts to run.
Documentation BEDJ 100/8-15-27-3 (6 l/s, 80m, 11kW) Fire Fighting System
Download instructions, catalog for BEDJ 100/8-15-27-3 (6 l/s, 80m, 11kW) Fire Fighting System
BEDJ 100/8-15-27-3 (6 l/s, 80m, 11kW) Fire Fighting System reviews
Help in selection
+38 067 360-71-01
Selection of mechanical seals
+38 095 656-37-57
Pump selection
If you have any questions when placing an order, or need help choosing a product, please contact the specified contacts.